#include "structs.h"
//Device name should be unique as it is used
//to identify the device for OTA updates.
#define deviceName "Heater"
/*Uncomment the operating mode you wish to use.
* Normal - Used for heating. If temp.cur < desired, turn on
* Inverse - Operates in the inverse. If temp.cur > desired turn on | This mode could be used for an exhaust fan to limit
* temperature or humidity. (Just feed in a humidity value instead of temperature.
*/
#define normalMode
//#define inverseMode
//Temerature settings
Temperature temp = {
95, //Current Temp (Don't change)
60 , //Target Temp
6 , //Temp Range
0 , //Mode (0:F or 1:C) (Not coded)
};
/*This amount of time must pass before the heater is allowd to turn back on (in seconds)
* Though this shouldn't be needed with the temp.offset, I wished to add it anyway.
* This is an anti-short cycle feature.
*/
int cooldownPeriod = 30;
// Max current allowed before disconnecting relay. Sonoff says the s31 is rated for 15 amps.
#define maxSafeLoad 15
// Cooldown before attempting to reconnect load
#define loadCooldown 30
// Attempts before giving up and leaving relay off until reset
#define loadConnectAttempts 3
//If you wish to forward the temperature to another device uncomment this line.
//And, add the token in "blynk.h"
#define forwardTemp